(Nagios)-check_hpasm[HP]

高小强的汽车暴晒场 2018-02-12

Nagios Check_hp HP

2014年11月18日

下午 08:49

https://IP:2381

[root@nagios ~]# tar zxvf check_hp_bladechassis-1.0.1.tar.gz

[root@nagios check_hp_bladechassis-1.0.1]# ./check_hp_bladechassis -H xxx.xxx.xxx.xxx

SNMP ERROR: Can't determine model name

[root@nagios check_hp_bladechassis-1.0.1]# snmpwalk -Os -c public -v 1 xxx.xxx.xxx

[root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx -C public

CRITICAL - snmpwalk returns no product name (cpqsinfo-mib), wrong device

windows端安装ilo驱动 (必须),先安装SNMPAgent(cp024529_log_th.exe cp024617_ilo_th.exe cp022559_hp_agents_w2008.exe)

[root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx

OK - System: 'proliant dl380p gen8', S/N: '*******', ROM: 'P70 03/01/2013', hardware working fine, da: 2 logical drives, 16 physical drives

Redhat系统下安装agent

[root@localhost ~]# rpm -ivh hpacucli-9.40-12.0.x86_64.rpm(不必须)

rpm -ivh hp-health-9.50-1631.33.rhel5.x86_64.rpm(必须)

rpm -ivh hp-snmp-agents-9.50-2564.34.rhel5.x86_64.rpm(必须)

/etc/init.d/hp-snmp-agents start

需要配置snmp

/sbin/hpsnmpconfig

/etc/init.d/hp-health restart

/etc/init.d/hp-asrd restart

/etc/init.d/hp-snmp-agents restart

其他Server访问不了

[root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx

CRITICAL - snmpwalk returns no product name (cpqsinfo-mib), wrong device

但本地能检查出数据,所以是snmp配置有误。

[root@localhost plugins-scripts]# ./check_hpasm

OK - System: 'proliant dl380p gen8', S/N: '*******', ROM: 'P70 03/01/2013', hardware working fine

Linux下配置snmp(可从其他机台copy过来)

[root@localhost plugins-scripts]# vim /etc/snmp/snmpd.conf

#add (网上参考) <http://javatechnology.iteye.com/blog/768001>

# sec.name source community

com2sec notConfigUser [監控主機] public

.1表示所有设备信息

viewsystemviewincluded.1

修改process checks(去掉注释)

# proc mountd

# proc ntalkd 4

# proc sendmail 10 1

修改Executables/scripts配置(去掉注释)

#exec echotest /bin/echo hello world

修改disk checks配置(去掉注释)

#disk / 10000

修改load average checks配置(去掉注释)

#load 12 14 14

[root@localhost plugins-scripts]# service snmpd restart

其他Server获取信息ok

[root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx

OK - System: 'proliant dl380p gen8', S/N: '*******', ROM: 'P70 03/01/2013', hardware working fine, da: 1 logical drives, 14 physical drives

注意:proliant dl380 gen9

rpm -ivh hp-health-10.10-1710.30.rhel6.x86_64.rpm

rpm -ihv hp-snmp-agents-10.10-2732.25.rhel6.x86_64.rpm

cp029394_ilo_Interface.exe

cp029429_ilo_Management.exe

cp030048_Agent.exe

http://www.hpiss.com/7740.html